Skip to main content
Erschienen in: Fire Technology 6/2023

11.08.2023

Evaluation of the Maximum Cognitive Distance Per Emergency Exit Sign Colour in a Smoke-Filled Environment Simulated Using a Translucent Eye Patch

verfasst von: Ryun-Seok Oh, Young-Chan Kim, Young-Hoon Bae, Jun-Ho Choi

Erschienen in: Fire Technology | Ausgabe 6/2023

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Exit signs are intended to help occupants promptly and accurately select evacuation paths during emergencies. However, according to previous studies and accident cases, exit signs are not helpful for occupants during emergency situations, which can be attributed to limited visibility due to the smoke generated during fires. Further, most exit sign installation standards do not consider exit sign visibility in smoke-filled environments. Thus, exit sign visibility can be considered to be low during actual fires. To overcome this issue, a means of improving visibility was investigated in this study by changing the exit sign color. A full-scale experiment was conducted to analyse the maximum cognitive distance (The maximum cognitive distance is defined as the greatest distance at which an observer can clearly identify the content of an exit sign) according to the exit sign safety colour in which a smoke-filled environment was simulated using a translucent eye patch. The smoke-filled environment was divided into nine levels of obstructed visibility according to the visibility distance when a translucent eye patch was worn. The maximum cognitive distance was measured for exit signs in seven safety colours (red, orange, yellow, green, blue, navy, and purple). The results showed that the mean maximum cognitive distances of the navy, purple, blue, and red exit signs were greater than that of the green exit sign, which is widely used currently. The navy, purple, blue, and red exit signs had mean maximum cognitive distances approximately 1.29 times, 1.23 times, 1.22 times, and 1.21 times longer than that of the green exit sign, respectively. The differences in the mean maximum cognitive distance were found to be statistically significant at a level of 0.05. This study’s analysis showed that these four colours had a greater contrast effect on the background colour (white) than green. Hence, the contrast difference between the safety colour and the background colour is considered the main parameter affecting cognitive performance for the exit sign lighting.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Literatur
4.
Zurück zum Zitat Klein R (1996) Düsseldorf Airport fire. Fire Eng. J 18–23 Klein R (1996) Düsseldorf Airport fire. Fire Eng. J 18–23
5.
Zurück zum Zitat Gutman D, Biffl WL, Suner S, Cioffi WG (2003) The station nightclub fire and disaster preparedness in rhode Island. R I Med J 86(11):344–346 Gutman D, Biffl WL, Suner S, Cioffi WG (2003) The station nightclub fire and disaster preparedness in rhode Island. R I Med J 86(11):344–346
6.
Zurück zum Zitat Kim T, Jeon G, Park K, Hong W (2003) The research and analysis of fire at the daegu subway (1)-the timetable and system for settlement resulted from fire of subway in daegu city. In: Proceedings of 2003 Autumn Annual Conference, Architectural Institute of Korea Planning & Design, vol 23(2):877–880 Kim T, Jeon G, Park K, Hong W (2003) The research and analysis of fire at the daegu subway (1)-the timetable and system for settlement resulted from fire of subway in daegu city. In: Proceedings of 2003 Autumn Annual Conference, Architectural Institute of Korea Planning & Design, vol 23(2):877–880
7.
Zurück zum Zitat Fennell D (1988) Investigation into the king’s cross underground fire. Her Majesty’s Stationery Office Publication Centre, London Fennell D (1988) Investigation into the king’s cross underground fire. Her Majesty’s Stationery Office Publication Centre, London
8.
Zurück zum Zitat Weinspach PM, Gundlach J, Klingelhofer H, Ries R, Schneider U (1997) Analysis of the fire On april 11th, 1996; recommendations and consequences for düsseldorf rhein-ruhr-airport. Staatskanzlei Nordrhein-Wstfalen, Mannesmannufer, Düsseldorf Weinspach PM, Gundlach J, Klingelhofer H, Ries R, Schneider U (1997) Analysis of the fire On april 11th, 1996; recommendations and consequences for düsseldorf rhein-ruhr-airport. Staatskanzlei Nordrhein-Wstfalen, Mannesmannufer, Düsseldorf
9.
Zurück zum Zitat Grosshandler W, Bryner N, Madrzykowski D, Kuntz K (2005) Report of the technical investigation of the station nightclub fire. NIST NCSTAR, Gaitherburg Grosshandler W, Bryner N, Madrzykowski D, Kuntz K (2005) Report of the technical investigation of the station nightclub fire. NIST NCSTAR, Gaitherburg
10.
Zurück zum Zitat Hong W, Jeon G (2005) A study on safe egress countermeasure in underground space through the analyzing survivors exit patterns of daegu city subway. JAIK 21(1):235–248 Hong W, Jeon G (2005) A study on safe egress countermeasure in underground space through the analyzing survivors exit patterns of daegu city subway. JAIK 21(1):235–248
12.
Zurück zum Zitat Bertin J (1983) Semiology of graphics: diagrams, networks, maps. Esri Press Books, Berlin Bertin J (1983) Semiology of graphics: diagrams, networks, maps. Esri Press Books, Berlin
13.
Zurück zum Zitat Ware C (2019) Information visualization: perception for design. Morgan Kaufmann, Cambridge Ware C (2019) Information visualization: perception for design. Morgan Kaufmann, Cambridge
16.
Zurück zum Zitat Bowers J (1999) Introduction to two-dimensional design: understanding form and function. Wiley, New York Bowers J (1999) Introduction to two-dimensional design: understanding form and function. Wiley, New York
17.
Zurück zum Zitat Birren F (2016) Color psychology and color therapy: a factual study of the influence of color on human life. Pickle Partners Publishing, New York Birren F (2016) Color psychology and color therapy: a factual study of the influence of color on human life. Pickle Partners Publishing, New York
18.
Zurück zum Zitat The British Standards Institution (20000) BS 5499-4: Safety signs, including fire safety signs-Part 4: Code of practice for escape route signing The British Standards Institution (20000) BS 5499-4: Safety signs, including fire safety signs-Part 4: Code of practice for escape route signing
19.
Zurück zum Zitat The British Standards Institution (2002) BS 5499–1: Graphical symbols and signs-Safety signs, including fire safety signs-Part 1: Specification for geometric shapes, colours and layout. The British Standards Institution (2002) BS 5499–1: Graphical symbols and signs-Safety signs, including fire safety signs-Part 1: Specification for geometric shapes, colours and layout.
20.
Zurück zum Zitat International Organization for Standardization (2011) ISO 3864-1: Graphical symbols-Safety colours and safety signs-Part 1: Design principles for safety signs and safety markings International Organization for Standardization (2011) ISO 3864-1: Graphical symbols-Safety colours and safety signs-Part 1: Design principles for safety signs and safety markings
21.
Zurück zum Zitat National Fire Protection Association (2021) NFPA 101: life safety code handbook, 15th edn. National Fire Protection Association, Quincy National Fire Protection Association (2021) NFPA 101: life safety code handbook, 15th edn. National Fire Protection Association, Quincy
22.
Zurück zum Zitat Korea National Fire Agency (2020) NFSC 303: fire safety standard on safety signs. National Fire Agency, Seoul Korea National Fire Agency (2020) NFSC 303: fire safety standard on safety signs. National Fire Agency, Seoul
23.
Zurück zum Zitat International Organization for Standardization (2019) ISO 7010: graphical symbols-Safety colours and safety signs-Registered safety signs International Organization for Standardization (2019) ISO 7010: graphical symbols-Safety colours and safety signs-Registered safety signs
24.
Zurück zum Zitat Choudhury AKR (2014) Principles of colour and appearance measurement: object appearance, colour perception and instrumental measurement. Elsevier, London Choudhury AKR (2014) Principles of colour and appearance measurement: object appearance, colour perception and instrumental measurement. Elsevier, London
25.
Zurück zum Zitat National Standard of the People’s republic of China (2015) GB 13495.1: Fire safety signs-Part 1: signs National Standard of the People’s republic of China (2015) GB 13495.1: Fire safety signs-Part 1: signs
26.
Zurück zum Zitat United Arab Emirates Ministry of Interior (2018) UAE Fire & Life Safety Code of Practice United Arab Emirates Ministry of Interior (2018) UAE Fire & Life Safety Code of Practice
27.
Zurück zum Zitat Nilsson D, Frantzich H, Saunders WL (2005) Coloured flashing lights to mark emergency exits—experiences from evacuation experiments. Fire Saf Sci 8:569–579CrossRef Nilsson D, Frantzich H, Saunders WL (2005) Coloured flashing lights to mark emergency exits—experiences from evacuation experiments. Fire Saf Sci 8:569–579CrossRef
40.
Zurück zum Zitat Tuomisaari M (1997) Visibility of exit signs and low-location lighting in smoky conditions. VTT, Technical Research Centre of Finland Tuomisaari M (1997) Visibility of exit signs and low-location lighting in smoky conditions. VTT, Technical Research Centre of Finland
41.
Zurück zum Zitat Yamada T, Kubota K, Abe N, Lida A (2004) Visibility of emergency exit signs and emergency lights through smoke. Fire Saf Sci 6:560–569 Yamada T, Kubota K, Abe N, Lida A (2004) Visibility of emergency exit signs and emergency lights through smoke. Fire Saf Sci 6:560–569
43.
Zurück zum Zitat Wright MS, Cook GK, Webber GMB (2001) Visibility of four exit signs and two exit door markings in smoke as gauged by twenty people. In: Second International Symposium on Human Behaviour in Fire, pp 147–157. Wright MS, Cook GK, Webber GMB (2001) Visibility of four exit signs and two exit door markings in smoke as gauged by twenty people. In: Second International Symposium on Human Behaviour in Fire, pp 147–157.
44.
Zurück zum Zitat Zhang Q (2010) Image based analysis of visibility in smoke laden environments. Doctoral Dissertation, University of Hull Zhang Q (2010) Image based analysis of visibility in smoke laden environments. Doctoral Dissertation, University of Hull
47.
Zurück zum Zitat Gwak Y, Ryoo S (2010) Representation of light spectrum using n-color dispersion photon mapping. J Korea Comput Graph Soc 16(2):39–45CrossRef Gwak Y, Ryoo S (2010) Representation of light spectrum using n-color dispersion photon mapping. J Korea Comput Graph Soc 16(2):39–45CrossRef
48.
Zurück zum Zitat Malacara D (2011) Color vision and colorimetry: theory and applications. SPIE Press, BellinghamCrossRef Malacara D (2011) Color vision and colorimetry: theory and applications. SPIE Press, BellinghamCrossRef
54.
Zurück zum Zitat Jin T (2002) Visibility and human behavior in fire smoke. In: DiNenno P (ed) The SFPE handbook of fire protection engineering, 3rd edn. National Fire Protection Association, Quincy Jin T (2002) Visibility and human behavior in fire smoke. In: DiNenno P (ed) The SFPE handbook of fire protection engineering, 3rd edn. National Fire Protection Association, Quincy
56.
Zurück zum Zitat Fahy RF, Proulx G (1995) Collective common sense: a study of human behavior during the world trade center evacuation. NFPA J 89:59–67 Fahy RF, Proulx G (1995) Collective common sense: a study of human behavior during the world trade center evacuation. NFPA J 89:59–67
57.
Zurück zum Zitat Korean Industrial Stnadards (2019) KS C 7613: methods of luminance measurements in lighting fileds Korean Industrial Stnadards (2019) KS C 7613: methods of luminance measurements in lighting fileds
58.
Zurück zum Zitat Korean Industrial Stnadards (2022) KS C 7612: Illuminance measurements for lighting installations. Korean Industrial Stnadards (2022) KS C 7612: Illuminance measurements for lighting installations.
60.
Zurück zum Zitat Hahn C (1964) The Korean near vision chart. J Korean Ophthalmol Soc 5(2):7–10 Hahn C (1964) The Korean near vision chart. J Korean Ophthalmol Soc 5(2):7–10
61.
Zurück zum Zitat Korea National Health Insurance Service (2019) Health Examination Statistics-Statistical Information Report Korea National Health Insurance Service (2019) Health Examination Statistics-Statistical Information Report
64.
Zurück zum Zitat Oh R (2016) A evaluation on perceptive effects of hue of exit sign classified by smoke density and maximum visible distance, Master’s dissertation, Pukyong National University, Busan, South Korea. Oh R (2016) A evaluation on perceptive effects of hue of exit sign classified by smoke density and maximum visible distance, Master’s dissertation, Pukyong National University, Busan, South Korea.
Metadaten
Titel
Evaluation of the Maximum Cognitive Distance Per Emergency Exit Sign Colour in a Smoke-Filled Environment Simulated Using a Translucent Eye Patch
verfasst von
Ryun-Seok Oh
Young-Chan Kim
Young-Hoon Bae
Jun-Ho Choi
Publikationsdatum
11.08.2023
Verlag
Springer US
Erschienen in
Fire Technology / Ausgabe 6/2023
Print ISSN: 0015-2684
Elektronische ISSN: 1572-8099
DOI
https://doi.org/10.1007/s10694-023-01474-9

Weitere Artikel der Ausgabe 6/2023

Fire Technology 6/2023 Zur Ausgabe