Skip to main content

15.04.2024 | Original Article

Flow diverters treatment planning of small- and medium-sized intracranial saccular aneurysms on the internal carotid artery via constraint-based virtual deployment

verfasst von: Zehua Liu, Meng Zhang, Chao Wang, Zhongxiao Wang, Xiangyun Liao, Chubin Ou, Weixin Si

Erschienen in: International Journal of Computer Assisted Radiology and Surgery

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Purpose

The internal carotid artery (ICA) is a region with a high incidence for small- and medium-sized saccular aneurysms. However, the treatment relies heavily on the surgeon’s experience to achieve optimal outcome. Although the finite element method (FEM) and computational fluid dynamics can predict the postoperative outcomes, due to the computational complexity of traditional methods, there is an urgent need for investigating the fast but versatile approaches related to numerical simulations of flow diverters (FDs) deployment coupled with the hemodynamic analysis to determine the treatment plan.

Methods

We collected the preoperative and postoperative data from 34 patients (29 females, 5 males; mean age 55.74 ± 9.98 years) who were treated with a single flow diverter for small- to medium-sized intracranial saccular aneurysms on the ICA. The constraint-based virtual deployment (CVD) method is proposed to simulate the FDs expanding outward along the vessel centerline while be constrained by the inner wall of the vessel.

Results

The results indicate that there were no significant differences in the reduction rates of wall shear stress and aneurysms neck velocity between the FEM and methods. However, the solution time of CVD was greatly reduced by 98%.

Conclusion

In the typical location of small- and medium-sized saccular aneurysms, namely the ICA, our virtual FDs deployment simulation effectively balances the computational accuracy and efficiency. Combined with hemodynamics analysis, our method can accurately represent the blood flow changes within the lesion region to assist surgeons in clinical decision-making.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Bouillot P, Brina O, Ouared R, Yilmaz H, Farhat M, Erceg G, Lovblad KO, Vargas MI, Kulcsar Z, Pereira VM (2016) Geometrical deployment for braided stent. Med Image Anal 30:85–94CrossRefPubMed Bouillot P, Brina O, Ouared R, Yilmaz H, Farhat M, Erceg G, Lovblad KO, Vargas MI, Kulcsar Z, Pereira VM (2016) Geometrical deployment for braided stent. Med Image Anal 30:85–94CrossRefPubMed
2.
Zurück zum Zitat Bouillot P, Brina O, Yilmaz H, Farhat M, Erceg G, Lovblad KO, Vargas M, Kulcsar Z, Pereira V (2016) Virtual-versus-real implantation of flow diverters: clinical potential and influence of vascular geometry. Am J Neuroradiol 37(11):2079–2086CrossRefPubMedPubMedCentral Bouillot P, Brina O, Yilmaz H, Farhat M, Erceg G, Lovblad KO, Vargas M, Kulcsar Z, Pereira V (2016) Virtual-versus-real implantation of flow diverters: clinical potential and influence of vascular geometry. Am J Neuroradiol 37(11):2079–2086CrossRefPubMedPubMedCentral
3.
Zurück zum Zitat Chancellor B, Raz E, Shapiro M, Tanweer O, Nossek E, Riina HA, Nelson PK (2020) Flow diversion for intracranial aneurysm treatment: trials involving flow diverters and long-term outcomes. Neurosurgery 86(Supplement–1):S36–S45CrossRefPubMed Chancellor B, Raz E, Shapiro M, Tanweer O, Nossek E, Riina HA, Nelson PK (2020) Flow diversion for intracranial aneurysm treatment: trials involving flow diverters and long-term outcomes. Neurosurgery 86(Supplement–1):S36–S45CrossRefPubMed
4.
Zurück zum Zitat Dobrocky T, Matzinger M, Piechowiak EI, Kaesmacher J, Pilgram-Pastor S, Goldberg J, Bervini D, Klail T, Pereira VM, Z’Graggen W et al (2023) Benefit of advanced 3D DSA and MRI/CT fusion in neurovascular pathology. Clin Neuroradiol 1–8 Dobrocky T, Matzinger M, Piechowiak EI, Kaesmacher J, Pilgram-Pastor S, Goldberg J, Bervini D, Klail T, Pereira VM, Z’Graggen W et al (2023) Benefit of advanced 3D DSA and MRI/CT fusion in neurovascular pathology. Clin Neuroradiol 1–8
5.
Zurück zum Zitat Frösen J, Cebral J, Robertson AM, Aoki T (2019) Flow-induced, inflammation-mediated arterial wall remodeling in the formation and progression of intracranial aneurysms. Neurosurg Focus 47(1):E21CrossRefPubMedPubMedCentral Frösen J, Cebral J, Robertson AM, Aoki T (2019) Flow-induced, inflammation-mediated arterial wall remodeling in the formation and progression of intracranial aneurysms. Neurosurg Focus 47(1):E21CrossRefPubMedPubMedCentral
6.
Zurück zum Zitat Gory B, Berge J, Bonafé A, Pierot L, Spelle L, Piotin M, Biondi A, Cognard C, Mounayer C, Sourour N et al (2019) Flow diverters for intracranial aneurysms: the diversion national prospective cohort study. Stroke 50(12):3471–3480CrossRefPubMed Gory B, Berge J, Bonafé A, Pierot L, Spelle L, Piotin M, Biondi A, Cognard C, Mounayer C, Sourour N et al (2019) Flow diverters for intracranial aneurysms: the diversion national prospective cohort study. Stroke 50(12):3471–3480CrossRefPubMed
7.
Zurück zum Zitat Guédon A, Thépenier C, Shotar E, Gabrieli J, Mathon B, Premat K, Lenck S, Degos V, Sourour N, Clarençon F (2021) Predictive score for complete occlusion of intracranial aneurysms treated by flow-diverter stents using machine learning. J Neurointerv Surg 13(4):341–346CrossRefPubMed Guédon A, Thépenier C, Shotar E, Gabrieli J, Mathon B, Premat K, Lenck S, Degos V, Sourour N, Clarençon F (2021) Predictive score for complete occlusion of intracranial aneurysms treated by flow-diverter stents using machine learning. J Neurointerv Surg 13(4):341–346CrossRefPubMed
8.
Zurück zum Zitat Izzo R, Steinman D, Manini S, Antiga L (2018) The vascular modeling toolkit: a python library for the analysis of tubular structures in medical images. J Open Source Softw 3(25):745CrossRef Izzo R, Steinman D, Manini S, Antiga L (2018) The vascular modeling toolkit: a python library for the analysis of tubular structures in medical images. J Open Source Softw 3(25):745CrossRef
9.
Zurück zum Zitat Leng X, Wang Y, Xu J, Jiang Y, Zhang X, Xiang J (2018) Numerical simulation of patient-specific endovascular stenting and coiling for intracranial aneurysm surgical planning. J Transl Med 16(1):1–10CrossRef Leng X, Wang Y, Xu J, Jiang Y, Zhang X, Xiang J (2018) Numerical simulation of patient-specific endovascular stenting and coiling for intracranial aneurysm surgical planning. J Transl Med 16(1):1–10CrossRef
10.
Zurück zum Zitat Li CZ, Liu RQ, Zhong HX, Fan JM, Si WX, Zhang M, Heng PA (2023) Semi-supervised intracranial aneurysm segmentation from CTA images via weight-perceptual self-ensembling model. J Comput Sci Technol 38(3):674–685CrossRef Li CZ, Liu RQ, Zhong HX, Fan JM, Si WX, Zhang M, Heng PA (2023) Semi-supervised intracranial aneurysm segmentation from CTA images via weight-perceptual self-ensembling model. J Comput Sci Technol 38(3):674–685CrossRef
11.
Zurück zum Zitat Ma D, Dumont TM, Kosukegawa H, Ohta M, Yang X, Siddiqui AH, Meng H (2013) High fidelity virtual stenting (HIFIVS) for intracranial aneurysm flow diversion: in vitro and in silico. Ann Biomed Eng 41:2143–2156CrossRefPubMedPubMedCentral Ma D, Dumont TM, Kosukegawa H, Ohta M, Yang X, Siddiqui AH, Meng H (2013) High fidelity virtual stenting (HIFIVS) for intracranial aneurysm flow diversion: in vitro and in silico. Ann Biomed Eng 41:2143–2156CrossRefPubMedPubMedCentral
12.
Zurück zum Zitat Ogilvy CS, Chua MH, Fusco MR, Reddy AS, Thomas AJ (2015) Stratification of recanalization for patients with endovascular treatment of intracranial aneurysms. Neurosurgery 76(4):390CrossRefPubMed Ogilvy CS, Chua MH, Fusco MR, Reddy AS, Thomas AJ (2015) Stratification of recanalization for patients with endovascular treatment of intracranial aneurysms. Neurosurgery 76(4):390CrossRefPubMed
13.
Zurück zum Zitat Ou C, Hou X, Duan CZ, Zhang X, Chong W, Qian Y (2021) Flow diverter modeled as heterogeneous and anisotropic porous medium: simulation, experimental validation and case analysis. J Biomech 123:110525CrossRefPubMed Ou C, Hou X, Duan CZ, Zhang X, Chong W, Qian Y (2021) Flow diverter modeled as heterogeneous and anisotropic porous medium: simulation, experimental validation and case analysis. J Biomech 123:110525CrossRefPubMed
14.
Zurück zum Zitat Paliwal N, Yu H, Xu J, Xiang J, Siddiqui AH, Yang X, Li H, Meng H (2016) Virtual stenting workflow with vessel-specific initialization and adaptive expansion for neurovascular stents and flow diverters. Comput Methods Biomech Biomed Engin 19(13):1423–1431CrossRefPubMedPubMedCentral Paliwal N, Yu H, Xu J, Xiang J, Siddiqui AH, Yang X, Li H, Meng H (2016) Virtual stenting workflow with vessel-specific initialization and adaptive expansion for neurovascular stents and flow diverters. Comput Methods Biomech Biomed Engin 19(13):1423–1431CrossRefPubMedPubMedCentral
15.
Zurück zum Zitat Ravindran K, Casabella AM, Cebral J, Brinjikji W, Kallmes DF, Kadirvel R (2020) Mechanism of action and biology of flow diverters in the treatment of intracranial aneurysms. Neurosurgery 86(Suppl 1):S13CrossRefPubMed Ravindran K, Casabella AM, Cebral J, Brinjikji W, Kallmes DF, Kadirvel R (2020) Mechanism of action and biology of flow diverters in the treatment of intracranial aneurysms. Neurosurgery 86(Suppl 1):S13CrossRefPubMed
16.
Zurück zum Zitat Ruan X, Yuan W, Hu Y, Li J, Wu W, Xia R (2020) Chiral constrained stent: Effect of structural design on the mechanical and intravascular stent deployment performances. Mech Mater 148:103509CrossRef Ruan X, Yuan W, Hu Y, Li J, Wu W, Xia R (2020) Chiral constrained stent: Effect of structural design on the mechanical and intravascular stent deployment performances. Mech Mater 148:103509CrossRef
17.
Zurück zum Zitat Sarrami-Foroushani A, Lassila T, MacRaild M, Asquith J, Roes KC, Byrne JV, Frangi AF (2021) In-silico trial of intracranial flow diverters replicates and expands insights from conventional clinical trials. Nat Commun 12(1):3861CrossRefPubMedPubMedCentral Sarrami-Foroushani A, Lassila T, MacRaild M, Asquith J, Roes KC, Byrne JV, Frangi AF (2021) In-silico trial of intracranial flow diverters replicates and expands insights from conventional clinical trials. Nat Commun 12(1):3861CrossRefPubMedPubMedCentral
18.
Zurück zum Zitat Wu X, Tian Z, Liu J, Li W, Chen J, Zhou Y, Yang X, Mu S (2019) Hemodynamic impacts of flow diverter devices on the ophthalmic artery. J Transl Med 17(1):1–7CrossRef Wu X, Tian Z, Liu J, Li W, Chen J, Zhou Y, Yang X, Mu S (2019) Hemodynamic impacts of flow diverter devices on the ophthalmic artery. J Transl Med 17(1):1–7CrossRef
19.
Zurück zum Zitat Závodszky G, Csippa B, Paál G, Szikora I (2020) A novel virtual flow diverter implantation method with realistic deployment mechanics and validated force response. Int J Numer Methods Biomed Eng 36(6):e3340CrossRef Závodszky G, Csippa B, Paál G, Szikora I (2020) A novel virtual flow diverter implantation method with realistic deployment mechanics and validated force response. Int J Numer Methods Biomed Eng 36(6):e3340CrossRef
20.
Zurück zum Zitat Zhang X, Wu D, Miao F, Liu H, Li Y (2020) Personalized hemodynamic modeling of the human cardiovascular system: a reduced-order computing model. IEEE Trans Biomed Eng 67(10):2754–2764CrossRefPubMed Zhang X, Wu D, Miao F, Liu H, Li Y (2020) Personalized hemodynamic modeling of the human cardiovascular system: a reduced-order computing model. IEEE Trans Biomed Eng 67(10):2754–2764CrossRefPubMed
Metadaten
Titel
Flow diverters treatment planning of small- and medium-sized intracranial saccular aneurysms on the internal carotid artery via constraint-based virtual deployment
verfasst von
Zehua Liu
Meng Zhang
Chao Wang
Zhongxiao Wang
Xiangyun Liao
Chubin Ou
Weixin Si
Publikationsdatum
15.04.2024
Verlag
Springer International Publishing
Erschienen in
International Journal of Computer Assisted Radiology and Surgery
Print ISSN: 1861-6410
Elektronische ISSN: 1861-6429
DOI
https://doi.org/10.1007/s11548-024-03124-z

Premium Partner