Skip to main content
Erschienen in: Measurement Techniques 7/2023

07.12.2023 | MECHANICAL MEASUREMENTS

Influence of the variable geometry of the flow switch nozzle exit on the metrological characteristics of a calibration unit with weighing devices

verfasst von: A. A. Korneev, A. V. Shchelchkov, R. A. Korneev

Erschienen in: Measurement Techniques | Ausgabe 7/2023

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

This article discusses the issues regarding the improvement of the metrological characteristics, weight, dimensions, and technical and economic indicators of calibration units with weighing devices because of the introduction of a flow switch with variable nozzle exit geometry to their design. The use of this flow switch design can solve the problem of filling the nozzle exit with water, reduce the dimensions of the hydraulic path, simplify the maintenance procedure, and minimize the cost of installation. This work describes the design, operating principle, and timing diagram of a flow switch with variable nozzle exit geometry. Herein, the local hydrodynamic characteristics of water flow were investigated using a Pitot tube with changes in the nozzle exit width and mass flow rate in the range of 25–550 t/h. Moreover, the optimal values of the nozzle exit width were experimentally determined based on the value of the liquid mass flow rate, at which it is filled with water. Using a comparison standard, the metrological characteristics of a calibration unit with weighing devices, which include a flow switch with variable nozzle exit geometry, were analyzed in a wide range of liquid mass flow rates. Additionally, the impact of the nozzle exit width on the metrological characteristics of a calibration unit with weighing devices in the investigated range of liquid flow was established. Dependency diagrams of the expanded measurement uncertainty of the installation when reproducing the unit of liquid mass flow rate on the measurement time interval and the liquid mass flow rate are demonstrated here. From the results, the optimal values of the nozzle exit width and measurement time intervals were determined based on the liquid mass flow rates when using a flow switch with variable nozzle exit geometry. Furthermore, the operation range expansion of weighing devices, which are part of the calibration units with weighing devices, is justified. The proposed design of the flow switch with variable nozzle exit geometry is recommended for use in the design and modernization of operated calibration units with weighing devices of flow switches.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Fußnoten
1
GOST 8.631-2013 (OIML R 60:2000). State System for Ensuring Uniform Measurement. Weight Sensors. General Technical Requirements. Test Methods.
 
2
GOST R 8.909-2016. State System for Ensuring Uniform Measurement. Secondary Standards of Units of Mass and Volume Flow, Mass and Volume of Liquid. Basic Metrological and Technical Requirements.
 
3
MI 3665-2022. Recommendation. State System for Ensuring the Uniformity of Measurements. Verification Installations. Verification Method.
 
4
SanPiN 2.1.4.1074-01. Drinking Water. Hygienic Requirements for Water Quality of Centralized Drinking Water Supply Systems. Quality Control. Hygienic Requirements for Ensuring the Safety of Hot Water Supply Systems.
 
5
Order of Rosstandart No. 3394 dated December 27, 2019 “On Approval of the State Primary Special Standard of Units of Mass and Volume of Liquid in a Flow, Mass and Volume Flow Rates of Liquid.”.
 
Literatur
9.
Zurück zum Zitat R. A. Korneev, A. R. Tukhvatullin, V. A. Fafurin, A. V. Shchelchkov, and A. I. Ataeva, “Measurement uncertainties estimation introduced by the diverter into the budget of standard uncertainties,” Proceedings of 18th International Flow Measurement Conference—FLOMEKO 2019, Lisbon , Portugal, 26–28 June, IMEKO, 161254 (2019). R. A. Korneev, A. R. Tukhvatullin, V. A. Fafurin, A. V. Shchelchkov, and A. I. Ataeva, “Measurement uncertainties estimation introduced by the diverter into the budget of standard uncertainties,” Proceedings of 18th International Flow Measurement Conference—FLOMEKO 2019, Lisbon , Portugal, 26–28 June, IMEKO, 161254 (2019).
10.
Zurück zum Zitat A. A. Korneev, A. M. Korneev, A. V. Shchelchkov, and D. V. Kraev, Patent RU 2781556 C1, Inventions. Utility models, No. 29 (2022). A. A. Korneev, A. M. Korneev, A. V. Shchelchkov, and D. V. Kraev, Patent RU 2781556 C1, Inventions. Utility models, No. 29 (2022).
13.
Zurück zum Zitat T. Meng, C. Wang, F. Gao, C. Xing, and L. Zhang, “Design and experimental analysis of transfer standard in water flow comparison,” 16th International Flow Measurement Conference, FLOMEKO 2013, Paris, 24–26 September, 2013, IMECO, Curran Associates, Inc., 50–60 (2014). T. Meng, C. Wang, F. Gao, C. Xing, and L. Zhang, “Design and experimental analysis of transfer standard in water flow comparison,” 16th International Flow Measurement Conference, FLOMEKO 2013, Paris, 24–26 September, 2013, IMECO, Curran Associates, Inc., 50–60 (2014).
Metadaten
Titel
Influence of the variable geometry of the flow switch nozzle exit on the metrological characteristics of a calibration unit with weighing devices
verfasst von
A. A. Korneev
A. V. Shchelchkov
R. A. Korneev
Publikationsdatum
07.12.2023
Verlag
Springer US
Erschienen in
Measurement Techniques / Ausgabe 7/2023
Print ISSN: 0543-1972
Elektronische ISSN: 1573-8906
DOI
https://doi.org/10.1007/s11018-023-02250-5

Weitere Artikel der Ausgabe 7/2023

Measurement Techniques 7/2023 Zur Ausgabe

GENERAL PROBLEMS OF METROLOGY AND MEASUREMENT TECHNIQUES

Analysis of operation models of complex technical systems