Abstract
A new experimental facility was realized at the PTB for reduced-background radiation thermometry under vacuum. This facility serves three purposes: (i) providing traceable calibration of space-based infrared remote-sensing experiments in terms of radiation temperature from −173 °C to 430 °C and spectral radiance; (ii) meeting the demand of industry to perform radiation thermometric measurements under vacuum conditions; and (iii) performing spectral emissivity measurements in the range from 0 °C to 430 °C without atmospheric interferences. The general concept of the reduced background calibration facility is to connect a source chamber with a detector chamber via a liquid nitrogen-cooled beamline. Translation and alignment units in the source and detector chambers enable the facility to compare and calibrate different sources and detectors under vacuum. In addition to the source chamber, a liquid nitrogen-cooled reference blackbody and an indium fixed-point blackbody radiator are connected to the cooled beamline on the radiation side. The radiation from the various sources is measured with a vacuum infrared standard radiation thermometer (VIRST) and is also imaged on a vacuum Fourier-transform infrared spectrometer (FTIR) to allow for spectrally resolved measurements of blackbodies and emissivity samples. Determination of the directional spectral emissivity will be performed in the temperature range from 0 °C to 430 °C for angles from 0° to ±70° with respect to normal incidence in the wavelength range from 1 μm to 1,000 μm.
Similar content being viewed by others
References
Ohring G., Wielicki B., Spencer R., Emery B., Datla R.: Bull. Am. Meteorol. Soc. 86, 1303 (2005)
J. Hollandt, R. Friedrich, B. Gutschwager, D.R. Taubert, J. Hartmann, High Temp. High Press. 35/36, 379 (2003/2006)
Lohrengel J., Todtenhaupt R., Ragab M.: Wärme- und Stoffübertragung 28, 6 (1993)
Ivanov V.S., Lisiansky B.E., Morozova S.P., Sapritsky V.I., Melenevsky U.A., Xi L.Y., Pei L.: Metrologia 37, 599 (2000)
S. Morozova, N.A. Parfentiev, B.E. Lisiansky, V.I. Sapritsky, N.L. Dovgilov, U.A. Melenevsky, B. Gutschwager, C. Monte, J. Hollandt, in Proceedings of TEMPMEKO 2007, Int. J. Thermophys. 29, 341 (2008). doi:10.1007/s10765-007-0355-z
B. Gutschwager, J. Hollandt, T. Jankowski, R. Gärtner, in Proceedings of TEMPMEKO 2007, Int. J. Thermophys. 29, 330 (2008). doi:10.1007/s10765-007-0349-x
J. Hollandt, B. Gutschwager, T. Jankowski, R. Gärtner, in TEMPERATUR 2006, ed. by J. Hollandt, S. Rudtsch (Berlin, 2006), pp. 71–79
Revercomb H.E., Buijs H., Howell H.B., LaPorte D.D., Smith W.L., Sromovsky L.A.: Appl. Optics 27, 3210 (1988)
Sromovsky L.A.: Appl. Optics 42, 1779 (2003)
Author information
Authors and Affiliations
Corresponding author
Additional information
References to commercial products are provided for identification purposes only and constitute neither endorsement nor representation that the item identified is the best available for the stated purpose.
Rights and permissions
About this article
Cite this article
Monte, C., Gutschwager, B., Morozova, S.P. et al. Radiation Thermometry and Emissivity Measurements Under Vacuum at the PTB. Int J Thermophys 30, 203–219 (2009). https://doi.org/10.1007/s10765-008-0442-9
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10765-008-0442-9