Abstract

Base isolation is a technique that has been used to protect structures from the damaging effect of earthquakes. The addition of isolators at the base improves the building structures’ adaptability. The majority of the fundamental isolation solutions created over time only offer “partial” isolation. “Partial” in the sense that the structure's flexibility and energy dissipation mechanisms, along with the incorporation of base isolation devices, are mostly responsible for reducing the force transferred and the ensuing responsive motions. U-shaped hybrid (steel plus rubber) dampers dissipate energy through elasto-plastic deformation and control earthquake ground motion. The aim of this research is to assess the effectiveness of a U-shaped hybrid system in reducing base shear and storey drift. In this research, the effectiveness of a U-shaped damper is compared to that of a lead rubber bearing (LRB) isolator by attaching it to a five-storey building. Using SAP2000 software, nonlinear time history analysis was carried out. This research found that the use of a U-shaped hybrid isolator was beneficial in minimizing structural responses, which may result in less damage.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Mazza F, Mazza M, Vulcano A (2018) Base-isolation systems for the seismic retrofitting of RC framed buildings with soft-storey subjected to near-fault earthquakes. Soil Dyn Earthq Eng 109:209–221CrossRef Mazza F, Mazza M, Vulcano A (2018) Base-isolation systems for the seismic retrofitting of RC framed buildings with soft-storey subjected to near-fault earthquakes. Soil Dyn Earthq Eng 109:209–221CrossRef
2.
Zurück zum Zitat Torunbalci N, Ozpalanlar G (2008) Earthquake response analysis of mid-story buildings isolated with various seismic isolation techniques. In: The 14th world conference on earthquake engineering, Beijing, China Torunbalci N, Ozpalanlar G (2008) Earthquake response analysis of mid-story buildings isolated with various seismic isolation techniques. In: The 14th world conference on earthquake engineering, Beijing, China
3.
Zurück zum Zitat Keerthana S, Kumar KS, Balamonica K, Jagannathan DS (2014) Seismic response control using base isolation strategy. Int J Emerg Technol Adv Eng. ISSN, 2250–2459 Keerthana S, Kumar KS, Balamonica K, Jagannathan DS (2014) Seismic response control using base isolation strategy. Int J Emerg Technol Adv Eng. ISSN, 2250–2459
4.
Zurück zum Zitat Shirule PA, Jagtap LP, Sonawane KR, Patil TD, Jadwanir N, Sonar SK (2012) Time history analysis of base isolated multi-storyed building 5:809–816 Shirule PA, Jagtap LP, Sonawane KR, Patil TD, Jadwanir N, Sonar SK (2012) Time history analysis of base isolated multi-storyed building 5:809–816
5.
Zurück zum Zitat Deosarkar MU, Gowardhan SD (2015) Non linear dynamic response of combined isolation system on symmetric and asymmetric buildings. IJIFR 3(3):1021–1035, Nov 2015, p-ISSN: 2347-1697 Deosarkar MU, Gowardhan SD (2015) Non linear dynamic response of combined isolation system on symmetric and asymmetric buildings. IJIFR 3(3):1021–1035, Nov 2015, p-ISSN: 2347-1697
6.
Zurück zum Zitat Murota N, Suzuki S, Mori T, Wakishima K, Sadan B, Tuzun C, Sutcu F, Erdik M (2021) Performance of high-damping rubber bearings for seismic isolation of residential buildings in Turkey. Soil Dyn Earthq Eng 143:106620CrossRef Murota N, Suzuki S, Mori T, Wakishima K, Sadan B, Tuzun C, Sutcu F, Erdik M (2021) Performance of high-damping rubber bearings for seismic isolation of residential buildings in Turkey. Soil Dyn Earthq Eng 143:106620CrossRef
7.
Zurück zum Zitat Bagheri S, Barghian M, Saieri F, Farzinfar A (2015) U-shaped metallic-yielding damper in building structures: seismic behavior and comparison with a friction damper. Structures (3):163–171. Elsevier Bagheri S, Barghian M, Saieri F, Farzinfar A (2015) U-shaped metallic-yielding damper in building structures: seismic behavior and comparison with a friction damper. Structures (3):163–171. Elsevier
8.
Zurück zum Zitat Sravya GJS, Manchalwar A (2019) Seismic isolation system using U-shaped steel damper. Int J Recent Technol Eng 8:12336–12339 Sravya GJS, Manchalwar A (2019) Seismic isolation system using U-shaped steel damper. Int J Recent Technol Eng 8:12336–12339
9.
Zurück zum Zitat Ebadi Jamkhaneh M, Ebrahimi AH, Shokri Amiri M (2019) Experimental and numerical investigation of steel moment resisting frame with U-shaped metallic yielding damper. Int J Steel Struct 19:806–818CrossRef Ebadi Jamkhaneh M, Ebrahimi AH, Shokri Amiri M (2019) Experimental and numerical investigation of steel moment resisting frame with U-shaped metallic yielding damper. Int J Steel Struct 19:806–818CrossRef
10.
Zurück zum Zitat Manchalwar A, Bakre SV (2020) Seismic performance of structure with isolated foundation using u-shape steel damper as an isolator. Soil Mech Found Eng 57:170–177CrossRef Manchalwar A, Bakre SV (2020) Seismic performance of structure with isolated foundation using u-shape steel damper as an isolator. Soil Mech Found Eng 57:170–177CrossRef
11.
Zurück zum Zitat Su L, Ahmadi G, Tadjbakhsh IG (1991) Performance of sliding resilient-friction base-isolation system. J Struct Eng 117(1):165–181CrossRef Su L, Ahmadi G, Tadjbakhsh IG (1991) Performance of sliding resilient-friction base-isolation system. J Struct Eng 117(1):165–181CrossRef
12.
Zurück zum Zitat Mishra P, Awchat GD (2017) Lead rubber bearings as base isolating devices for the construction of earthquake resistant structures-a review. SSRG Int J Civ Eng (SSRG-IJCE) 4(7):18–20 Mishra P, Awchat GD (2017) Lead rubber bearings as base isolating devices for the construction of earthquake resistant structures-a review. SSRG Int J Civ Eng (SSRG-IJCE) 4(7):18–20
13.
Zurück zum Zitat IS 456 (2000) Plain and reinforced concrete-code of practice (fourth revision). BIS, New Delhi, India IS 456 (2000) Plain and reinforced concrete-code of practice (fourth revision). BIS, New Delhi, India
14.
Zurück zum Zitat IS 13920 (2016) Ductile detailing of reinforced concrete structures subjected to seismic forces-code of practice. BIS, New Delhi, India IS 13920 (2016) Ductile detailing of reinforced concrete structures subjected to seismic forces-code of practice. BIS, New Delhi, India
15.
Zurück zum Zitat SAP2000, Integrated software for structural analysis & design, technical reference manual. Computers & Structures, Inc. SAP2000, Integrated software for structural analysis & design, technical reference manual. Computers & Structures, Inc.
Metadaten
Titel
Seismic Analysis of Five-Storied Building Using U-Shaped Hybrid Isolator and Lead Rubber Bearing Isolator
verfasst von
Srushti Gaikwad
Priti R. Satarkar
A. Manchalwar
Copyright-Jahr
2024
Verlag
Springer Nature Singapore
DOI
https://doi.org/10.1007/978-981-99-9610-0_38